Guangzhou MeCan Medical Limited

Guangzhou MeCan Medical Limited One - Stop Medical Equipment Supplier

Manufacturer from China
Active Member
9 Years
Home / Products / Ophthalmic Equipment /

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Contact Now
Guangzhou MeCan Medical Limited
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MrAndy
Contact Now

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Ask Latest Price
Video Channel
Brand Name :Mecan
Model Number :MC-OCT2000
Certification :ISO
Place of Origin :Guangzhou
MOQ :1 set
Price :USD1-39999/set
Payment Terms :L/C, T/T, Western Union, MoneyGram,Cash
Supply Ability :1000 sets/year
Delivery Time :3-15 working days
Packaging Details :carton
Item :Optical Coherence Tomography
Resolution(in tissue) :Axial 5.0μm;Transverse:15μm
Scanning range :Depth 2.5mm;Wide≥6mm
Light source :SLD.840nm
Scanning speed :≥27000 A-scans/sec.
Light power :750μW on cornea
Fixation :Internal and external fixation
Minimun pupil diameter :3mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Efficient automatic image acquisition

Easy guided macular or disc scan.

Quickly switch to anterior segment mode

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Precise positioning of the scan area, easy to focus on the lesion

Easily select the scan area for image acquisition.

Expanded field of view.

Focus on the lesion

Scan area positioning requires minimal

patients' cooperation

Double-click reset the scan area to the center.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Plenty of report templates and editable modules

A variety of default report templates to expedite the report generation.

Template design feature facilitates the diagnoses writing.

Electronic reports in PDF format are convenient for doctors and patients to read and save.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Unique community for consultation, teaching, and case study

Extensive cases to browse and search.

Enhanced teaching function.

Post and search comments to make consultation easier.

Unique lesion contour measurement function

You can quickly and easily correct the inaccurate contour lines generated by the automatic algorithm. The correct contour lines can be saved for future analysis, such as thickness topographic map and 3D map

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Unique disc edge identification function

Automatically measure the cup-disc ratio, rim area and other optometric parameters.

Automatically identify and draw the disc contour and cup contour in the fundus image.

You can correct the disc contour on the fundus map to accurately calculate the area of the disc and cup.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Precise follow-up scan technology

Automatically record the location of each inspection and repeat the data collection at the exact same locatior of the last inspection by using the image registration algorithm.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Details of the disease development can be found in the rich and colorful follow-up report.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Anterior segment analysis

Angle measurement: You can measure the anterior chamber angle, distance between the iris and any point on posterior comeal surface, anterior chamber area.

Corneal measurement You can measure the corneal vertex thickness after refractive error correction and the thickness between any upper and lower surfaces.


3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Accurate Glaucoma analysis

A single measurement can automatically evaluate the average thickness of the retinal nerve fiber layer in each sector.

Glaucoma follow-up analysis and comparison between left and right eyes show intuitive diagnostic details.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Macular thickness analysis

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Efficient 3D analysis

3D analysis: Rotate, zoom, layered, sliced, reconstruction, retinal vascular map, save and print 3D map,3D topographic map report.

3Mm Minimun Pupil Diameter Optical Coherence Tomography With Efficient 3d Analysis

Specification of our OCT

Resolution(in tissue) Axial 5.0μm;Transverse:15μm
Scanning range Depth 2.5mm;Wide≥6mm
Light source SLD.840nm
Scanning speed ≥27000 A-scans/sec.
Light power 750μW on cornea
Fixation Internal and external fixation
Minimun pupil diameter 3mm
Scan pattern 3D scanning,Radial scanning,Raster scanning.Circular scanning,HD scanning
Software analysis

Macular thickness topography, Average thickness of 9-sector,

Macular thickness map, Disc thickness tomography,

Disc thickness map,

Circumpapillary clock hour distribution,

Cup-to-disc ratio, Disc/cup/rim area,

Comparative analysis of disc circular scan between left and

right eyes, 3D analysis,

Follow-up analysis, HD scan analysis.

Anterior segment module

Scan pattern

Software analysis

Cornea scanning, Anterior chamber angle scanning.

Cornea thickness map,

Cornea thickness topography,

Cornea curvature topography,

Cornea HD analysis,

Anterior chamber angle analysis.

Inquiry Cart 0