Guangzhou MeCan Medical Limited

Guangzhou MeCan Medical Limited One - Stop Medical Equipment Supplier

Manufacturer from China
Active Member
9 Years
Home / Products / First Aid Equipment /

Trolley First Aid Equipment mechanical ventilation machine With Compressed Air

Contact Now
Guangzhou MeCan Medical Limited
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MrAndy
Contact Now

Trolley First Aid Equipment mechanical ventilation machine With Compressed Air

Ask Latest Price
Video Channel
Brand Name :MeCan
Model Number :PA-700BI
Certification :ISO
Place of Origin :GuangZhou
MOQ :1 set
Price :Inquiry
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :500 sets per week
Delivery Time :3-15 working dates
Packaging Details :Carton/Wooden packing
Product :ventilator
safety valve :<12.5 kPa
Respiratory Rate :1 ~ 99 bpm
Oxygen concentration output :21% ~ 100% adjustable
Maximum Minute ventilation :≥18L / min
modes of ventilation :A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance :≤30 Ml/kPa
Pressure limit range :1.0~ 6.0kPa
Display :10.4'' LCD Display
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Frist Aid Equipment 10.4''LCD Display Ventilator With Compressed Air

Model : PA-700BI

Prospective service and support

The PA-700BI ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

Display: 10.4''LCD Display Following Parameters & Real time waveform display

Operating mode and respiratory rate;

——Ventilator control frequency set by medical staff;

——Tidal volume of each breath in the patient;

——Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;

——Expiratory phase and inspiratory phase and actual respiratory rate;

Ventilator Construction:

--Environmental Protection Material construction, hardly to be broken.

-- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

TECHNIQUES SPECIFICATIONS
Physical specifications
Display 10.4'' LCD Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 1 ~ 99 bpm
Oxygen concentration output 21% ~ 100% adjustable
Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min; Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
1 set Oxygen tube
2 set Silicone Mask
1 pc Power line
4 pcs Threaded pipe
2 pcs Standard Pipe
1 set Oxygen Reducer
1 set Humidifier
1 pc Battery
2 set flow sensor
2 pcs A leather bag ( Blue)
1 set Tools with the machine
1 set User Manual (English Version)

Trolley First Aid Equipment mechanical ventilation machine With Compressed Air

Inquiry Cart 0