Mobile Operating Room Equipment Electric Suction Machine Medical Use Gynecology
Model: MCS-DFX-23D.I
Specification of Suction Canister:
MCS-DFX-23D.I
electrical suction units are new style mobile suction devices. They are devices for medical use designed for operations of gynecology in hospitals for taking out pus, blood, sputum and other thick liquid in human body.
F-eatures
◆ MCS-DFX-23D.I All-plastic ABS enclosure that is formed in one piece is adopted.
◆ The device is equipped with a imported membrane pump available with long service life.
◆ This device has low noise and is maintenance-free.
◆ This device is equipped with an overflow protection unit to prevent liquid from getting into pump body.
◆ It’s equipped with the hand-operated switch and footstep-operated switch.
Air pumping efficiency
Adjustment range of negative pressure
Noise level
Input power
Liquid vessel
TECHNICAL SPECIFICATION:
Power voltage:AC220V±10% 50Hz
Negative pressure:≥0.09MPa(680mmHg)
Suction rate:≥25L/min
Range of negative pressure:0.013MPa~0.09Mpa(680mmHg)
Suction bottle:2500ml x 2
Noise:≤55dB
Input power:400VA
Pump structure:Diaphragm type
Working type:intermittent loading,continuous operation
TECHNICAL SPECIFICATION: |
Power voltage:AC220V±10% 50Hz Negative pressure:≥0.09MPa(680mmHg) Suction rate:≥25L/min Range of negative pressure:0.013MPa~0.09Mpa(680mmHg) Suction bottle:2500ml x 2 Noise:≤55dB Input power:400VA Pump structure:Diaphragm type Working type:intermittent loading,continuous operation |
NOTE:
1.imported diaphragm pump
2.all ABS plastic shell
3.long service life time
4.glass bottle for cleaning & disinfection
5.oil-free pump is maintenance-free
6.low noise
7.with an overflow protection
DIMENSION (CM):37.5×36.5×50.5
PACKAGE: Carton
G.W. :15KG
MCS-DFX-23D.II
TECHNICAL SPECIFICATION:
Power voltage:AC220V±10% 50Hz
Negative pressure:≥0.09MPa(680mmHg)
Suction rate:≥25L/min
Range of negative pressure:0.013MPa~0.09Mpa(680mmHg)
Suction bottle:2500ml x 2
Noise:≤55dB
Input power:400VA
Pump structure:Diaphragm type
Working type:intermittent loading,continuous operation
TECHNICAL SPECIFICATION: |
Power voltage:AC220V±10% 50Hz Negative pressure:≥0.09MPa(680mmHg) Suction rate:≥25L/min Range of negative pressure:0.013MPa~0.09Mpa(680mmHg) Suction bottle:2500ml x 2 Noise:≤55dB Input power:400VA Pump structure:Diaphragm type Working type:intermittent loading,continuous operation |
NOTE:
1.imported diaphragm pump
2.long service life time
3.glass bottle for cleaning & disinfection
4.oil-free pump is maintenance-free
5.low noise
6.with an overflow protection
DIMENSION (CM):46×41×85
PACKAGE: Carton
G.W. :28KG