
Add to Cart
5.0 KW High Frequency Mobile Medical X Ray Machine with Table
Specifications of the Mobile Medical X Ray Machine
Power Output: 5KW
Main Inverter frequency: 40 KHz
X-ray Tube: fixed anode focus: 1.5 (X-ray tube for high frequency)
Tube Voltage: 40kV~~120KV (interval 1KV)
Tube Current: 25mA~~100mA
40~49kV 100mA 1~180mAs
50~59kV 77mA 1~140mAs
60~69kV 64mA 1~125mAs
70~79kV 55mA 1~110mAs
80~89kV 49mA 1~100mAs
90~99kV 44mA 1~80mAs
100~109kV 32mA 1~63mAs
110~120kV 25mA 1~50mAs
mAs 1.0~180mAs (46steps)
Power Supply: 220V±10% 50Hz
Inner-resistance ≤1.0Ω
Operation Method: Wire/wireless control
Features of the hot sale High Frequency Mobile X-ray Machine, medical x ray machine :
1. With compact appearance, flexible movement
2. With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures
3. With techniques of KV analog closed loop control, mAs digital closed loop control and micro-processing real-time control to ensure precision and repeatability of the dose.
4. With kV, mAs two button adjustment, LCD display, multifunction of safety guard.
5. With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.
6. With a high-quality knockdown X-ray generator to reduce irradiation, it is much safer to environment and operator.
7. With fault automatic protection setting and fault alarming display
8. The system can keep parameters automatic, in case losing data.
9. With a rotating beam limiting device to adjust the X-ray field and angle, so it can ensure accurate radiography results.
10. With high kV function, it has wide using range and good effect of photography.
11. Manual control and remote control are used to expose. Wireless remote exposure control can penetrate barriers, which makes operation more convenient.
Standard configurations of the hot sale High Frequency Mobile X-ray Machine, medical x ray machine :
Combined high-frequency high-voltage X-ray generator and high-frequency inverter power supply (5kW, 120kV, 100mA, 40 kHz) | one set |
New mobile X-ray photography mainframe | one set |
Mobile X-ray photography control system | one set |
Rotating beam limiting device | one set |
Remote control | one set |
Spare parts (See spare parts list for detail information) several |
Usage of the hot sale High Frequency Mobile X-ray Machine, medical x ray machine :
The machine is combined high-frequency X-ray photography diagnostic equipment, which is used in radiology, orthopedics, wards, emergency rooms, operating rooms, and ICU, etc. It is mobile diagnostic equipment which can make radiography on human body, such as head, limbs, chest and spine.
Parameters of the hot sale High Frequency Mobile X-ray Machine, medical x ray machine :
General-purpose, mobile X-ray system, dedicated for radiography of standing, seated or recumbent patients as well as for patients in bed or on the operating table and as a standby emergency unit. High-frequency X-ray generator with the following output:
1. Generator output: 5.0 kW
2. kV range: 40 kV - 120 kV in 1kv steps
3. mA range: 25~100 mA
4. Exposure time: 4 films per min, less than 20 ms per film
5. X-ray tube : Stationary anode tube with a focal spot of 1.5*1.5 mm
6. Collimator : bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
7.Power requirements :Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
8.Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
9.The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional ,different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.
10.The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs
The unit include, power plugs that are sufficient for the maximum voltage and current of the unit.
11. The maximum distance from the ground: ≥ 17500mm, and minimum distance from the ground :≤500mm, rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, The collimator can rotate 180 °